http://www.informixfaq.com/wiki/lib/images/favicon.icotext/html2021-04-22T13:28:24+00:00Paul Watsonwiki:sysmaster
http://www.informixfaq.com/wiki/doku.php/wiki:sysmaster?rev=1619098104&do=diff
What is Sysmaster
The window into the entire system, an area of shared memory with an SQL like interface
How to drop sysmaster
dbaccess sysmaster -
delete from systables where tabid > 99 and partnum < '0x100000';
delete from systables where tabname = 'sysdbspartn';
close database;
drop database sysmaster;
How long has the user been connected
select sid, username,
dbinfo('UTC_TO_DATETIME',connected) conection_time,
current - dbinfo('UTC_TO_DATETIME',con…text/html2014-04-22T15:27:56+00:00Paul Watsonuseful:presentation - created
http://www.informixfaq.com/wiki/doku.php/useful:presentation?rev=1398180476&do=diff
There are a lot of presentations out there, some of the public domains can be seen <http://www.oninit.com/presentations>text/html2014-04-22T15:26:25+00:00Paul Watsonwiki:navigation
http://www.informixfaq.com/wiki/doku.php/wiki:navigation?rev=1398180385&do=diff
Products
Installation
Configuration
Tuning
ER & HDR
Backup and Restore
Sysmaster
Onstat
SPL
Development
How do I ...
Trouble Shooting
Getting Support
Onlog
Presentations
Glossary
Useful Stuff
Maintainerstext/html2014-04-22T15:20:10+00:00Paul Watsonwiki:onstat
http://www.informixfaq.com/wiki/doku.php/wiki:onstat?rev=1398180010&do=diff
The onstat command is used to view and monitor what is happening in the engine.
Probably the Definitive (ish) Onstat Reference
There are PDA friendly access points as well, <http://www.oninit.com/onstat -u> - Some browsers, Chrome being one, will allow the spacestext/html2012-06-25T15:16:09+00:00Paul Watsonwiki:trouble
http://www.informixfaq.com/wiki/doku.php/wiki:trouble?rev=1340637369&do=diff
What status codes does onstat return?
You can check the current mode of IDS by checking the status ($?) after onstat -.
The values returned by 'onstat -' are:
-1/255 Offline
0 Initialisation
1 Quiescent
2 Recovery
3 Backup
4 Shutdown
5 Online
6 Abort
How can we see what's happening during a checkpoint?
Versions 9.40 and later support the environment variable TRACECKPTtext/html2012-05-23T16:58:13+00:00Paul Watsonerhdr:start
http://www.informixfaq.com/wiki/doku.php/erhdr:start?rev=1337792293&do=diff
Define Server Fails
Although this is a warning it is actually an error, the cdr define fails, the time delta between the servers is too large
15:24:03 CDR NIF site: 1 <grp_student3> clocks differ by -77279 seconds
15:24:03 Warning - The operating system time of day clock at the
remote site differs from the local site. This can
slow down the data-sync apply performace at the
target server. This happens only if timestamp or
stored procedure conflict resolut…text/html2012-01-12T23:24:26+00:00Paul Watsonwiki:howto
http://www.informixfaq.com/wiki/doku.php/wiki:howto?rev=1326410666&do=diff
What is currently installed
Check out the $INFORMIXDIR/etc/*cr files, this will list the various products and versions. The $INFORMIXDIR/etc/.snfile will also give you the installation order
Tell if the Engine is offline
command: onstat -u
INFORMIX-OnLine Version 7.14.UD2 -- On-Line -- Up 00:18:03 -- 147744 Kbytes If the words 'On-Line' do not appear in the returned line then there could be a problem. Check the log directly if the engine isn't running, otherwise use onstat -m
If the engin…